{"id":677,"date":"2024-07-23T19:18:25","date_gmt":"2024-07-23T18:18:25","guid":{"rendered":"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/?p=677"},"modified":"2024-07-23T19:18:25","modified_gmt":"2024-07-23T18:18:25","slug":"new-paper-moving-microcapillary-antibiotic-susceptibility-testing-mcast-towards-the-clinic-unravelling-kinetics-of-detection-of-uropathogenic-e-coli-mass-manufacturing-and-usability-for-detectio","status":"publish","type":"post","link":"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/new-paper-moving-microcapillary-antibiotic-susceptibility-testing-mcast-towards-the-clinic-unravelling-kinetics-of-detection-of-uropathogenic-e-coli-mass-manufacturing-and-usability-for-detectio\/","title":{"rendered":"New paper: Moving microcapillary antibiotic susceptibility testing (mcAST) towards the clinic: unravelling kinetics of detection of uropathogenic E. coli, mass-manufacturing and usability for detection of urinary tract infections in human urine"},"content":{"rendered":"<p>Inflammation-based point-of-care (PoC) diagnostic innovations are critical to prevent unnecessary antibiotic use and the development of antimicrobial resistance. Our research team confirmed that miniaturised phenotypic antibiotic susceptibility tests (AST) are compatible with conventional methods. Direct testing (without isolation) is particularly feasible for urinary tract infections, enabling the use of microfluidic AST systems in PoC. As the bacterial growth rate is temperature dependent, temperature control and mass production of microfluidic test strips in PoC are required.<\/p>\n<p>This study demonstrates the application of direct microcapillary AST (mcAST) from clinical specimens with minimal equipment and a smartphone camera. The test on 12 clinical specimens achieved 100% accuracy in detecting bacteria in urine and 95% categorical agreement with 4 antibiotics. The kinetic model showed that the degradation time of resazurin in microcapillaries was dependent on bacterial density. Furthermore, mass production of mcAST strips by air drying gave results in agreement with standard AST methods. These results bring mcAST closer to clinical application and make it possible to support antibiotic prescription decisions within one day at PoC.<\/p>\n<p>Check out the web link below to access the paper!<\/p>\n<p><a title=\"Moving microcapillary antibiotic susceptibility testing (mcAST) towards the clinic: unravelling kinetics of detection of uropathogenic E. coli, mass-manufacturing and usability for detection of urinary tract infections in human urine\" href=\"https:\/\/pubs.rsc.org\/en\/content\/articlelanding\/2023\/sd\/d2sd00138a\" target=\"_blank\" rel=\"noopener\">Moving microcapillary antibiotic susceptibility testing (mcAST) towards the clinic: unravelling kinetics of detection of uropathogenic E. coli, mass-manufacturing and usability for detection of urinary tract infections in human urine<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Inflammation-based point-of-care (PoC) diagnostic innovations are critical to prevent unnecessary antibiotic use and the development of antimicrobial resistance. Our research team confirmed that miniaturised phenotypic antibiotic susceptibility tests (AST) are&#8230;<a class=\"read-more\" href=\"&#104;&#116;&#116;&#112;&#115;&#58;&#47;&#47;&#114;&#101;&#115;&#101;&#97;&#114;&#99;&#104;&#46;&#114;&#101;&#97;&#100;&#105;&#110;&#103;&#46;&#97;&#99;&#46;&#117;&#107;&#47;&#98;&#105;&#111;&#109;&#101;&#100;&#105;&#99;&#97;&#108;&#45;&#116;&#101;&#99;&#104;&#110;&#111;&#108;&#111;&#103;&#121;&#45;&#108;&#97;&#98;&#47;&#110;&#101;&#119;&#45;&#112;&#97;&#112;&#101;&#114;&#45;&#109;&#111;&#118;&#105;&#110;&#103;&#45;&#109;&#105;&#99;&#114;&#111;&#99;&#97;&#112;&#105;&#108;&#108;&#97;&#114;&#121;&#45;&#97;&#110;&#116;&#105;&#98;&#105;&#111;&#116;&#105;&#99;&#45;&#115;&#117;&#115;&#99;&#101;&#112;&#116;&#105;&#98;&#105;&#108;&#105;&#116;&#121;&#45;&#116;&#101;&#115;&#116;&#105;&#110;&#103;&#45;&#109;&#99;&#97;&#115;&#116;&#45;&#116;&#111;&#119;&#97;&#114;&#100;&#115;&#45;&#116;&#104;&#101;&#45;&#99;&#108;&#105;&#110;&#105;&#99;&#45;&#117;&#110;&#114;&#97;&#118;&#101;&#108;&#108;&#105;&#110;&#103;&#45;&#107;&#105;&#110;&#101;&#116;&#105;&#99;&#115;&#45;&#111;&#102;&#45;&#100;&#101;&#116;&#101;&#99;&#116;&#105;&#111;&#110;&#45;&#111;&#102;&#45;&#117;&#114;&#111;&#112;&#97;&#116;&#104;&#111;&#103;&#101;&#110;&#105;&#99;&#45;&#101;&#45;&#99;&#111;&#108;&#105;&#45;&#109;&#97;&#115;&#115;&#45;&#109;&#97;&#110;&#117;&#102;&#97;&#99;&#116;&#117;&#114;&#105;&#110;&#103;&#45;&#97;&#110;&#100;&#45;&#117;&#115;&#97;&#98;&#105;&#108;&#105;&#116;&#121;&#45;&#102;&#111;&#114;&#45;&#100;&#101;&#116;&#101;&#99;&#116;&#105;&#111;&#47;\">Read More ><\/a><\/p>\n","protected":false},"author":503,"featured_media":678,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"_uf_show_specific_survey":0,"_uf_disable_surveys":false,"__cvm_playback_settings":[],"__cvm_video_id":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-677","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"acf":[],"aioseo_notices":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v21.8.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>New paper: Moving microcapillary antibiotic susceptibility testing (mcAST) towards the clinic: unravelling kinetics of detection of uropathogenic E. coli, mass-manufacturing and usability for detection of urinary tract infections in human urine - Needs et Al.<\/title>\n<meta name=\"description\" content=\"This study shows for the first-time application of microcapillary antibiotic susceptibility testing (mcAST) directly from clinical samples, using minimal equipment and simple liquid handling, and with kinetics of growth recorded using a smartphone camera.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/new-paper-moving-microcapillary-antibiotic-susceptibility-testing-mcast-towards-the-clinic-unravelling-kinetics-of-detection-of-uropathogenic-e-coli-mass-manufacturing-and-usability-for-detectio\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"New paper: Moving microcapillary antibiotic susceptibility testing (mcAST) towards the clinic: unravelling kinetics of detection of uropathogenic E. coli, mass-manufacturing and usability for detection of urinary tract infections in human urine - Needs et Al.\" \/>\n<meta property=\"og:description\" content=\"This study shows for the first-time application of microcapillary antibiotic susceptibility testing (mcAST) directly from clinical samples, using minimal equipment and simple liquid handling, and with kinetics of growth recorded using a smartphone camera.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/new-paper-moving-microcapillary-antibiotic-susceptibility-testing-mcast-towards-the-clinic-unravelling-kinetics-of-detection-of-uropathogenic-e-coli-mass-manufacturing-and-usability-for-detectio\/\" \/>\n<meta property=\"og:site_name\" content=\"Needs et Al.\" \/>\n<meta property=\"article:published_time\" content=\"2024-07-23T18:18:25+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/wp-content\/uploads\/sites\/107\/2024\/07\/2024-07-23-191552.png\" \/>\n\t<meta property=\"og:image:width\" content=\"387\" \/>\n\t<meta property=\"og:image:height\" content=\"227\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Ruya Meltem Sariyer\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Ruya Meltem Sariyer\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/new-paper-moving-microcapillary-antibiotic-susceptibility-testing-mcast-towards-the-clinic-unravelling-kinetics-of-detection-of-uropathogenic-e-coli-mass-manufacturing-and-usability-for-detectio\/\",\"url\":\"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/new-paper-moving-microcapillary-antibiotic-susceptibility-testing-mcast-towards-the-clinic-unravelling-kinetics-of-detection-of-uropathogenic-e-coli-mass-manufacturing-and-usability-for-detectio\/\",\"name\":\"New paper: Moving microcapillary antibiotic susceptibility testing (mcAST) towards the clinic: unravelling kinetics of detection of uropathogenic E. coli, mass-manufacturing and usability for detection of urinary tract infections in human urine - Needs et Al.\",\"isPartOf\":{\"@id\":\"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/#website\"},\"datePublished\":\"2024-07-23T18:18:25+00:00\",\"dateModified\":\"2024-07-23T18:18:25+00:00\",\"author\":{\"@id\":\"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/#\/schema\/person\/264fca56fa679ba80098c16e7e1209d3\"},\"description\":\"This study shows for the first-time application of microcapillary antibiotic susceptibility testing (mcAST) directly from clinical samples, using minimal equipment and simple liquid handling, and with kinetics of growth recorded using a smartphone camera.\",\"breadcrumb\":{\"@id\":\"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/new-paper-moving-microcapillary-antibiotic-susceptibility-testing-mcast-towards-the-clinic-unravelling-kinetics-of-detection-of-uropathogenic-e-coli-mass-manufacturing-and-usability-for-detectio\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/new-paper-moving-microcapillary-antibiotic-susceptibility-testing-mcast-towards-the-clinic-unravelling-kinetics-of-detection-of-uropathogenic-e-coli-mass-manufacturing-and-usability-for-detectio\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/new-paper-moving-microcapillary-antibiotic-susceptibility-testing-mcast-towards-the-clinic-unravelling-kinetics-of-detection-of-uropathogenic-e-coli-mass-manufacturing-and-usability-for-detectio\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"New paper: Moving microcapillary antibiotic susceptibility testing (mcAST) towards the clinic: unravelling kinetics of detection of uropathogenic E. coli, mass-manufacturing and usability for detection of urinary tract infections in human urine\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/#website\",\"url\":\"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/\",\"name\":\"Edwards Lab\",\"description\":\"Biomedical and pharmaceutical technology\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/#\/schema\/person\/264fca56fa679ba80098c16e7e1209d3\",\"name\":\"Ruya Meltem Sariyer\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/d744228be9f64f7cdfff55bc5a4cfbf6a8ef209d3f19ebc64b95b0c3b5880c23?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/d744228be9f64f7cdfff55bc5a4cfbf6a8ef209d3f19ebc64b95b0c3b5880c23?s=96&d=mm&r=g\",\"caption\":\"Ruya Meltem Sariyer\"},\"url\":\"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/author\/ki823648student-reading-ac-uk\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"New paper: Moving microcapillary antibiotic susceptibility testing (mcAST) towards the clinic: unravelling kinetics of detection of uropathogenic E. coli, mass-manufacturing and usability for detection of urinary tract infections in human urine - Needs et Al.","description":"This study shows for the first-time application of microcapillary antibiotic susceptibility testing (mcAST) directly from clinical samples, using minimal equipment and simple liquid handling, and with kinetics of growth recorded using a smartphone camera.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/new-paper-moving-microcapillary-antibiotic-susceptibility-testing-mcast-towards-the-clinic-unravelling-kinetics-of-detection-of-uropathogenic-e-coli-mass-manufacturing-and-usability-for-detectio\/","og_locale":"en_GB","og_type":"article","og_title":"New paper: Moving microcapillary antibiotic susceptibility testing (mcAST) towards the clinic: unravelling kinetics of detection of uropathogenic E. coli, mass-manufacturing and usability for detection of urinary tract infections in human urine - Needs et Al.","og_description":"This study shows for the first-time application of microcapillary antibiotic susceptibility testing (mcAST) directly from clinical samples, using minimal equipment and simple liquid handling, and with kinetics of growth recorded using a smartphone camera.","og_url":"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/new-paper-moving-microcapillary-antibiotic-susceptibility-testing-mcast-towards-the-clinic-unravelling-kinetics-of-detection-of-uropathogenic-e-coli-mass-manufacturing-and-usability-for-detectio\/","og_site_name":"Needs et Al.","article_published_time":"2024-07-23T18:18:25+00:00","og_image":[{"width":387,"height":227,"url":"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/wp-content\/uploads\/sites\/107\/2024\/07\/2024-07-23-191552.png","type":"image\/png"}],"author":"Ruya Meltem Sariyer","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Ruya Meltem Sariyer","Estimated reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/new-paper-moving-microcapillary-antibiotic-susceptibility-testing-mcast-towards-the-clinic-unravelling-kinetics-of-detection-of-uropathogenic-e-coli-mass-manufacturing-and-usability-for-detectio\/","url":"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/new-paper-moving-microcapillary-antibiotic-susceptibility-testing-mcast-towards-the-clinic-unravelling-kinetics-of-detection-of-uropathogenic-e-coli-mass-manufacturing-and-usability-for-detectio\/","name":"New paper: Moving microcapillary antibiotic susceptibility testing (mcAST) towards the clinic: unravelling kinetics of detection of uropathogenic E. coli, mass-manufacturing and usability for detection of urinary tract infections in human urine - Needs et Al.","isPartOf":{"@id":"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/#website"},"datePublished":"2024-07-23T18:18:25+00:00","dateModified":"2024-07-23T18:18:25+00:00","author":{"@id":"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/#\/schema\/person\/264fca56fa679ba80098c16e7e1209d3"},"description":"This study shows for the first-time application of microcapillary antibiotic susceptibility testing (mcAST) directly from clinical samples, using minimal equipment and simple liquid handling, and with kinetics of growth recorded using a smartphone camera.","breadcrumb":{"@id":"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/new-paper-moving-microcapillary-antibiotic-susceptibility-testing-mcast-towards-the-clinic-unravelling-kinetics-of-detection-of-uropathogenic-e-coli-mass-manufacturing-and-usability-for-detectio\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/new-paper-moving-microcapillary-antibiotic-susceptibility-testing-mcast-towards-the-clinic-unravelling-kinetics-of-detection-of-uropathogenic-e-coli-mass-manufacturing-and-usability-for-detectio\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/new-paper-moving-microcapillary-antibiotic-susceptibility-testing-mcast-towards-the-clinic-unravelling-kinetics-of-detection-of-uropathogenic-e-coli-mass-manufacturing-and-usability-for-detectio\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/"},{"@type":"ListItem","position":2,"name":"New paper: Moving microcapillary antibiotic susceptibility testing (mcAST) towards the clinic: unravelling kinetics of detection of uropathogenic E. coli, mass-manufacturing and usability for detection of urinary tract infections in human urine"}]},{"@type":"WebSite","@id":"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/#website","url":"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/","name":"Edwards Lab","description":"Biomedical and pharmaceutical technology","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-GB"},{"@type":"Person","@id":"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/#\/schema\/person\/264fca56fa679ba80098c16e7e1209d3","name":"Ruya Meltem Sariyer","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/d744228be9f64f7cdfff55bc5a4cfbf6a8ef209d3f19ebc64b95b0c3b5880c23?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d744228be9f64f7cdfff55bc5a4cfbf6a8ef209d3f19ebc64b95b0c3b5880c23?s=96&d=mm&r=g","caption":"Ruya Meltem Sariyer"},"url":"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/author\/ki823648student-reading-ac-uk\/"}]}},"cc_featured_image_caption":{"caption_text":"","source_text":"","source_url":""},"_links":{"self":[{"href":"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/wp-json\/wp\/v2\/posts\/677","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/wp-json\/wp\/v2\/users\/503"}],"replies":[{"embeddable":true,"href":"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/wp-json\/wp\/v2\/comments?post=677"}],"version-history":[{"count":1,"href":"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/wp-json\/wp\/v2\/posts\/677\/revisions"}],"predecessor-version":[{"id":679,"href":"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/wp-json\/wp\/v2\/posts\/677\/revisions\/679"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/wp-json\/wp\/v2\/media\/678"}],"wp:attachment":[{"href":"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/wp-json\/wp\/v2\/media?parent=677"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/wp-json\/wp\/v2\/categories?post=677"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/research.reading.ac.uk\/biomedical-technology-lab\/wp-json\/wp\/v2\/tags?post=677"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}